Uf b wire ampacity.
A 2 500 b 1 000 c 500 d 125 e 250 f 500.
View the southwire company 100 ft.
Or the cable type temperature limitation.
Jacket thickness for all nm b cable is 30 mils color code for 2 2 conductor cable is black white red and white with red stripe.
Uf b has a heat capacity of 90 c and is rated at 600 volt.
Where the number of current carrying conductors in a raceway or cable exceeds 3 the allowable ampacities shall be reduced per the table below.
Copper uf b view pdf.
Uf b wire s formal name refers to its uses.
Southwire s copper uf b cable is used in applications that include outside lamp posts pumps and other loads.
Underground feeder building wire assortment 112 69 1 13 ft 112 69 1 13 ft free delivery.
Low energy circuit cable type uf single conductor view pdf.
Access control cable view pdf.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating.
Uf b cable is typically used as an underground feeder cable to distribute power from an existing building to outdoor lighting fixtures pumps outbuildings and other outdoor equipment.
The equipment temperature limitation default values as described in nec 110 14 c 1.
Ampacities per national electrical code section 310 15 and 334 80 2011 edition note.
Color code for 4 conductor cable is black white red and blue.
Copper tffn tfn tewn view pdf.
The calculator will permit choosing nm b and uf b up to 2 awg.
Nec tables are based on table 310 15 b 16 formerly table 310 16 allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c not more than three current carrying conductors in raceway cable or earth directly buried based on ambient temperature of 30 c.
U nderground f eeder and b ranch circuit wiring cable applications.
What does ufb mean.
Table 310 15 b 3 a adjustment factors for more than three current carrying conductors in a raceway or cable.
Burglar alarm cable view pdf.
The app limits the final ampacity of the wire to the most conservative of.
The cable can also be used as direct burial cable.
Usually a general purpose house circuit is designed for 20.
Nm b is permitted to be.
Annunciator bell wire view pdf.
Allowable ampacities of insulated conductors rated 0 2000 volts as excerpted from the 2002 national electrical code ampacities of not more than three current carrying conductors in raceway cable or earth.
Current is measured in amperes or amps.
Copper rhh rhw 2 use 2 view pdf.
Category 5e cable view pdf.
It can also be used for outbuildings such as garages and barns.